#11
![]() |
|||
|
|||
![]()
On Tue, 21 Sep 2010 10:15:19 -0700 (PDT), The Gardener
wrote: On Sep 20, 11:38*pm, Charles Ellson wrote: On Mon, 20 Sep 2010 13:03:29 -0700 (PDT), The Gardener wrote: On Sep 20, 8:37*pm, Denis McMahon wrote: On 20/09/10 20:19, Dominic wrote: On London Underground the DC traction current circuit to and from the trains is via an insulated third live rail and an insulated fourth live rail, and the earthed running rails are not used for traction current. Would it be possible to use an isolation transformer to prevent the electrocution of a person who touched one of the live rails on this type of railway, or possibly on an AC version of it? My understanding, which I am sure will be corrected, is that an isolation transformer could prevent the electrocution of a person who connected one live rail to earth, but would not prevent the electrocution of a person who connected the third live rail and fourth live rail together. I would be very grateful to anyone who can explain further. Transformers don't work for DC, and aiui the 4th (return) rail exists to reduce the corrosion effects of stray currents in the rather moist environment of the tunnels. The LU system is not completely isolated from earth. The rails are loosely tied to earth at the substation (IIRC ~400ohms +ve to earth, ~200ohms negative to earth) to maintain the conductor rails at about +420v and -210v; should an earth fault occur on either rail then the equipment at the substation detects this providing an alarm (and tripping the supply ?). Correct. In particular, the use of fourth rails was the result of the use of cast-iron segments to line the tunnels, as these would have been very vulnerable to corrosion. To prevent the live rail - running rail shock risk, isolate the traction supplies from the running rails. However, I suspect that not having either side of the traction supply tied to earth brings back those stray current corrosion issues, and / or it may have other issues too, like affecting track circuits. Rgds Denis McMahon Not directly earthing the traction return system is the best means to prevent stray current corrosion. There is still some form of earthing at the substation otherwise this would produce a floating supply (generally deprecated in the electrical world) which in very dry conditions could allow hazardous voltages to exist on the traction return rail. Adding to the previous comments re isolation transformers (which is what you would actually have if the electricity supplier's substation supply side did not have one pole deliberately earthed), the existence of an isolated/non-earthed supply or supplies (in the absence of "double-insulation" measures or similar used in domestic equipment) enables faults which involve the addition of normally separate supplies to dangerous levels even if each individual supply is at a safe voltage. On the railway this could result in e.g. a 630v 4-rail supply being charged by a broken overhead line at 1500V, 25kV or more if the 4-rail supply had no earth connection at all. The return path is designed to tie it as close as possible to the substation earth by providing a low resistance but also avoiding the opportunity for a deliberate or accidental earthing of the return path at any point away from the substation. http://www.wsatkins.co.uk/Images/The...a%20at%20Inter... [http://tinyurl.com/34skod2] shows arrangements for DC and AC supplies for overhead electrification. IIRC there is a Railway Group Standard showing DC traction supply arrangements (which I can't find ATM) which indicates earthing of one side of the supply at the substation BUT at NO OTHER point outwith the substation (as you indicate/imply above). I know which standard you mean - like you I can't find it at the moment! http://www.rgsonline.co.uk/Railway_G...ing%20Stock/Ot... [http://tinyurl.com/24cubfk] (a withdrawn document) Deals with traction bonding (but not the supply origin), including :- "5.1 The design of the return circuits shall be such that there are no deliberate points of contact with the general mass of the earth." On a third-rail line, the running rails are mounted on insulated fastenings for this reason, and the negative busbar at a DC substation is insulated from earth. No third rail system can ever be immune to stray current corrosion, espacially at an AC/DC interface as the running rails at such points must be earthed, but it can be managed to a level that is ALARP (As Low As Reasonably Practicable). The drawbacks of a fourth rail system are (a) additional complexity for the pway and pick-up arrangements and (b) only one rail for the return circuit (on third rail systems, both running rails are used for traction return, No they aren't. _One_ of the running rails is normally used for traction return as can often be discerned by the difference between the traction bonds on one running rail and the much smaller signalling bonds on the other side where there is a break (other than an insulated break) in a running rail. The other running rail is generally used for track circuits. On the Southern, both running rails are used for traction return. Ah! Maybe it was a mistake to think the SR would do it the same way as the LMS. Track circuits are AC as a result; historically 50 Hz but modern track circuits (known as TI for Traction Immune) use higher frequencies (I believe in the range 1.1-1.3 kHz) to avoid the risk of harmonics in the return current giving a false clear indication. This was a particular problem with Networkers, which is why they are still prohibited from large areas of the Southern. Single rail track circuits are, however, used where there are switches and crossings. http://www.rgsonline.co.uk/Railway_G...%20Iss%201.pdf [http://tinyurl.com/3ypbo7n] has a few pictures which might save a few thousand words. Impedance bonds are used to separate track circuits. ICBW but I also understand that the Tyne and Wear Metro uses both rails for traction return. AIUI, only the Euston - Watford DC line And NLL (where still DC) and WLL ? uses only one running rail for traction return and this is why the redundant fourth rail remains north of Harrow and Wealdstone; it is bonded to the return rail to reduce the return circuit resistance. IMU rather to prevent increasing it IYSWIM (see also "chicken and egg") as it was originally designed as 4-rail with substations spaced appropriately. The use of one rail for traction return is, of course, standard practice on AC lines. |
#12
![]() |
|||
|
|||
![]()
Charles Ellson wrote:
On Tue, 21 Sep 2010 10:15:19 -0700 (PDT), The Gardener wrote: On Sep 20, 11:38 pm, Charles Ellson wrote: On Mon, 20 Sep 2010 13:03:29 -0700 (PDT), The Gardener wrote: On Sep 20, 8:37 pm, Denis McMahon wrote: On 20/09/10 20:19, Dominic wrote: On London Underground the DC traction current circuit to and from the trains is via an insulated third live rail and an insulated fourth live rail, and the earthed running rails are not used for traction current. Would it be possible to use an isolation transformer to prevent the electrocution of a person who touched one of the live rails on this type of railway, or possibly on an AC version of it? My understanding, which I am sure will be corrected, is that an isolation transformer could prevent the electrocution of a person who connected one live rail to earth, but would not prevent the electrocution of a person who connected the third live rail and fourth live rail together. I would be very grateful to anyone who can explain further. Transformers don't work for DC, and aiui the 4th (return) rail exists to reduce the corrosion effects of stray currents in the rather moist environment of the tunnels. The LU system is not completely isolated from earth. The rails are loosely tied to earth at the substation (IIRC ~400ohms +ve to earth, ~200ohms negative to earth) to maintain the conductor rails at about +420v and -210v; should an earth fault occur on either rail then the equipment at the substation detects this providing an alarm (and tripping the supply ?). Correct. In particular, the use of fourth rails was the result of the use of cast-iron segments to line the tunnels, as these would have been very vulnerable to corrosion. To prevent the live rail - running rail shock risk, isolate the traction supplies from the running rails. However, I suspect that not having either side of the traction supply tied to earth brings back those stray current corrosion issues, and / or it may have other issues too, like affecting track circuits. Rgds Denis McMahon Not directly earthing the traction return system is the best means to prevent stray current corrosion. There is still some form of earthing at the substation otherwise this would produce a floating supply (generally deprecated in the electrical world) which in very dry conditions could allow hazardous voltages to exist on the traction return rail. Adding to the previous comments re isolation transformers (which is what you would actually have if the electricity supplier's substation supply side did not have one pole deliberately earthed), the existence of an isolated/non-earthed supply or supplies (in the absence of "double-insulation" measures or similar used in domestic equipment) enables faults which involve the addition of normally separate supplies to dangerous levels even if each individual supply is at a safe voltage. On the railway this could result in e.g. a 630v 4-rail supply being charged by a broken overhead line at 1500V, 25kV or more if the 4-rail supply had no earth connection at all. The return path is designed to tie it as close as possible to the substation earth by providing a low resistance but also avoiding the opportunity for a deliberate or accidental earthing of the return path at any point away from the substation. http://www.wsatkins.co.uk/Images/The...a%20at%20Inter... [http://tinyurl.com/34skod2] shows arrangements for DC and AC supplies for overhead electrification. IIRC there is a Railway Group Standard showing DC traction supply arrangements (which I can't find ATM) which indicates earthing of one side of the supply at the substation BUT at NO OTHER point outwith the substation (as you indicate/imply above). I know which standard you mean - like you I can't find it at the moment! http://www.rgsonline.co.uk/Railway_G...ing%20Stock/Ot... [http://tinyurl.com/24cubfk] (a withdrawn document) Deals with traction bonding (but not the supply origin), including :- "5.1 The design of the return circuits shall be such that there are no deliberate points of contact with the general mass of the earth." On a third-rail line, the running rails are mounted on insulated fastenings for this reason, and the negative busbar at a DC substation is insulated from earth. No third rail system can ever be immune to stray current corrosion, espacially at an AC/DC interface as the running rails at such points must be earthed, but it can be managed to a level that is ALARP (As Low As Reasonably Practicable). The drawbacks of a fourth rail system are (a) additional complexity for the pway and pick-up arrangements and (b) only one rail for the return circuit (on third rail systems, both running rails are used for traction return, No they aren't. _One_ of the running rails is normally used for traction return as can often be discerned by the difference between the traction bonds on one running rail and the much smaller signalling bonds on the other side where there is a break (other than an insulated break) in a running rail. The other running rail is generally used for track circuits. On the Southern, both running rails are used for traction return. Ah! Maybe it was a mistake to think the SR would do it the same way as the LMS. Track circuits are AC as a result; historically 50 Hz but modern track circuits (known as TI for Traction Immune) use higher frequencies (I believe in the range 1.1-1.3 kHz) to avoid the risk of harmonics in the return current giving a false clear indication. This was a particular problem with Networkers, which is why they are still prohibited from large areas of the Southern. Single rail track circuits are, however, used where there are switches and crossings. http://www.rgsonline.co.uk/Railway_G...%20Iss%201.pdf [http://tinyurl.com/3ypbo7n] has a few pictures which might save a few thousand words. Impedance bonds are used to separate track circuits. ICBW but I also understand that the Tyne and Wear Metro uses both rails for traction return. AIUI, only the Euston - Watford DC line And NLL (where still DC) and WLL ? uses only one running rail for traction return and this is why the redundant fourth rail remains north of Harrow and Wealdstone; it is bonded to the return rail to reduce the return circuit resistance. IMU rather to prevent increasing it IYSWIM (see also "chicken and egg") as it was originally designed as 4-rail with substations spaced appropriately. The use of one rail for traction return is, of course, standard practice on AC lines. Although IIRC, the action of the autotransformers along the line ensures that traction return current is only carried by the track in the section the train is in. Beyond that section it is in the opposite phase of the (centre-tapped) 50Kv supply, Jim Hawkins |
#13
![]() |
|||
|
|||
![]()
On 21/09/10 18:15, The Gardener wrote:
On the Southern, both running rails are used for traction return. Track circuits are AC as a result; historically 50 Hz but modern track circuits (known as TI for Traction Immune) use higher frequencies (I believe in the range 1.1-1.3 kHz) to avoid the risk of harmonics in the return current giving a false clear indication. I thought modern track circuits transmit a digital code so as to completely eliminate the risk of traction systems generating the appropriate frequency? -roy |
#14
![]() |
|||
|
|||
![]()
On Wed, 22 Sep 2010 12:41:37 +0100, Roy Badami
wrote: On 21/09/10 18:15, The Gardener wrote: On the Southern, both running rails are used for traction return. Track circuits are AC as a result; historically 50 Hz but modern track circuits (known as TI for Traction Immune) use higher frequencies (I believe in the range 1.1-1.3 kHz) to avoid the risk of harmonics in the return current giving a false clear indication. I thought modern track circuits transmit a digital code so as to completely eliminate the risk of traction systems generating the appropriate frequency? Some possibly do but it can take many years for innovations to spread when you consider that semaphore signalling is still in use long after the introduction of colour-light signalling. |
#15
![]() |
|||
|
|||
![]()
On Sep 22, 12:41*pm, Roy Badami wrote:
On 21/09/10 18:15, The Gardener wrote: On the Southern, both running rails are used for traction return. Trackcircuits are AC as a result; historically 50 Hz but moderntrack circuits (known as TI for Traction Immune) use higher frequencies (I believe in the range 1.1-1.3 kHz) to avoid the risk of harmonics in the return current giving a false clear indication. I thought moderntrackcircuits transmit a digital code so as to completely eliminate the risk of traction systems generating the appropriate frequency? * * *-roy You're thinking of the HVI (High Voltage Impulse) type. These are used where there is a risk of low wheel-rail adhesion causing the train to "disappear" from the system. TI types are generally more common. HTH. |
#16
![]() |
|||
|
|||
![]()
On Oct 10, 11:18*am, The Gardener wrote:
On Sep 22, 12:41*pm, Roy Badami wrote: I thought moderntrackcircuits transmit a digital code so as to completely eliminate the risk of traction systems generating the appropriate frequency? * * *-roy You're thinking of the HVI (High Voltage Impulse) type. These are used where there is a risk of low wheel-rail adhesion causing the train to "disappear" from the system. TI types are generally more common. HVI track circuits are hardly modern though. I suspect he's thinking of something like the FS3000 track circuit from Invensys: http://www.invensysrail.com/download...4nZFuk9QJL.pdf |
#17
![]() |
|||
|
|||
![]()
On Sep 21, 11:08*pm, Charles Ellson
wrote: On Tue, 21 Sep 2010 10:15:19 -0700 (PDT), The Gardener wrote: AIUI, only the Euston - Watford DC line And NLL (where still DC) and WLL ? uses only one running rail for traction return and this is why the redundant fourth rail remains north of Harrow and Wealdstone; it is bonded to the return rail to reduce the return circuit resistance. IMU rather to prevent increasing it IYSWIM (see also "chicken and egg") as it was originally designed as 4-rail with substations spaced appropriately. Agreed! Apologies for not responding to this one sooner: to confirm, the WLL is electrified on Southern principles and uses both running rails for traction return. The sole surviving DC section of the NLL (Acton Central to Gunnersbury Junction) uses one rail. One of the odd consequences of the re-electrification of the NLL was that the DC section to Gunnersbury is now isolated. A new twin-transformer/ rectifier substation had to be built at Acton Central as the original sub only had one transformer/rectifier unit, and there would then have been no contingency if that had failed. The logical (ISTM) solution of putting in a new sub in the Gunnersbury area and supplying it from the Southern's 33 kV distribution system was not, for some reason, considered. As a result, an 11 kV feeder runs from Acton Lane solely to supply Acton Central. |
Reply |
|
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Police delete London tourists' photos 'to prevent terrorism' | London Transport | |||
Police delete London tourists' photos 'to prevent terrorism' | London Transport | |||
Bombed train removed from tracks | London Transport | |||
Northern line tracks reversed? | London Transport | |||
The Singing Tracks at Turnham Green | London Transport |