On Tue, 2 Dec 2008 07:49:35 +0000, "Clive D. W. Feather"
wrote: In article , Steve Fitzgerald ] writes Traction current is fed at +420v (positive) on the outside rails and - 210v on the centre rail (negative) the sum of these giving a traction feed of 630v dc. They are 'loosely' tied to earth through resistances in the sub stations that feed the supply. Despite being an electrician in a previous life and now a driver, I struggle to get my head round 'loosely tied to earth' and what it means in real life. There are resistors (I've seen various figures between 1 ohm and a few hundred ohms) connecting the power rails to earth. Because they are in a 2:1 ratio, in the absence of anything odd going on you get a small current flowing through those resistors and thus a potential divider. For example: +----- +ve{630V supply}-ve -----| | | Outer Centre rail rail | | |----[210ohm]---+---[105ohm]----| | | | | Ground In the idle state, there will be 630V across the pair of resistors which add up to 315 ohms, meaning 2 amps will flow through them. Since the central tap is grounded, the outer rail will be at +420V relative to ground and the centre rail at +210V. Suppose that something shorts the centre rail to ground, bridging out the 105 ohm resistor. We now have: +----- +ve{630V supply}-ve -----| | | Outer Centre rail rail | | |----[210ohm]---+---------------| | | (short) | | Ground The centre rail is at ground potential and the outer rail is at 630V because of the power supply. 3A now flows through the resistor. If, instead, we short the outer rail to ground, a similar change happens. Finally, what happens if some strange event causes a 210V potential between the outer rail and ground? We get: +----- +ve{630V supply}-ve -----| | | Outer Centre rail rail | | |----[210ohm]---+---[105ohm]----| | | | |----{210V}-----| | | | Ground The difference between the 210V and the 630V supply means that the centre rail will spring to -420V relative to ground. There will be a 1A flow through the 210 ohm resistor and a 4A flow through the 105V resistor. In other words, the resistors keep the rails at the +420V/-210V position *unless* something else happens to alter this. Hence "loosely tied". But at all times (absent a major short) the two rails are 630V apart. They can be both at the same potential if there is a break between one conductor rail feed and the substation (or only one of the pair of switches feeding from the next section is closed) and you have a train in section. There will be no voltage between the rails but they will definitely be alive, leaving a trap for anyone who ignores the standard "do not touch any rail" warnings, |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Harrow & Wealdstone lifts | London Transport | |||
Harrow & Wealdstone this morning! | London Transport | |||
Bakerloo Line beyond Harrow & Wealdstone | London Transport | |||
Bakerloo Line beyond Harrow & Wealdstone | London Transport | |||
Harrow & Wealdstone platforms | London Transport |